P.O. BOX 5486 Katy, TX 77491 PH.: 281-398-0004 FAX: 281-398-0007
|
|
|
GTI's Fume collection hood and baghouse system consists of a hood enclosure and baghouse, with ductwork of PVC. Air flow is determined using the method outlined in the American Council of Governmental Industrial Hygienists handbook on industrial ventilation. Please be aware that a permit to construct is usually required for air control equipment, and we will assist you in filing the necessary documents.
Hood Enclosure
The floor mounted truss structure is supported on columns on the working side of the kettle which in turn supports sliding doors along the side of the kettle. The opposite side of the kettle is enclosed by a similar structure which also supports sliding doors, and the ends of the kettle are served with gate type doors which open away from the working side. The sliding doors are suspended on ball bearing rollers mounted in track, and the end doors are mounted in ball bushings for ease of operation. 2. Crane Mounted Curtain - Perpendicular arrangement only The bridge crane supports a hanging curtain fabricated from PVC warehouse door strips that reach down to the top of the floor mounted truss. When the bridge crane is in position over the kettle, this hanging curtain forms the middle portion of the hood. (This is not necessary on a parallel kettle orientation served by a monorail.) 3. Roof Mounted Curtain A similar arrangement of PVC strips or sheet metal panels encloses the area from the ceiling down to the top of the bridge crane (or the top of the floor mounted hood in the case of a parallel kettle). When the crane is in position above the kettle, this hanging curtain completes the hood enclosure. 4. Roof Mounted Plenum A plenum constructed of the same material as the building roof which is approximately 4 feet square and the length of the kettle is positioned on the roof above the kettle. A slot 8 to 12" wide is cut in the roof along the length of the kettle, and fumes from the kettle are drawn into the plenum by the baghouse suction. Baghouse
Bags - 156 bags in each chamber - 5" dia. by 9'-2" polyester fabric Approximately 2000 sq. ft. cloth area each chamber Bag Cleaning - manual shaking based on pressure drop combined with a sonic horn Blower - 8,000 cfm @ 6"wc - 15Hp 480/3/60 with weather cover Precoat - Furnished with GTI automatic precoat unit Manometer - 0 - 8" wc Finish - interior and exterior epoxy painted Electrical - motor starters (25Hp & 1Hp) are furnished by client Ductwork - 24" diameter PVC ductwork will be specified from the roof mounted plenum to the baghouse inlet |