Feature
|
Description
|
| Option |
Option
Description
|
Burner
Model
|
|
|
|
1
|
Burner
Model
|
|
0050
|
Model
Size 0050
|
|
|
|
0100
|
Model
Size 0100
|
|
|
|
0150
|
Model
Size 0150
|
|
|
|
0200
|
Model
Size 0200
|
|
|
|
0250
|
Model
Size 0250
|
|
|
|
0300
|
Model
Size 0300
|
|
|
|
0350
|
Model
Size 0350
|
|
|
|
0400
|
Model
Size 0400
|
|
|
|
|
2
|
Burner
Style
|
|
|
3
|
Air
Supply
|
|
A
|
Integral
Packaged Blower
|
ALL
|
|
|
X
|
No
Blower
|
ALL
|
|
|
|
4
|
Fuel Type
|
|
B
|
Butane
(C4H10)
|
ALL
|
|
|
N
|
Natural
Gas (CH4)
|
ALL
|
|
|
P
|
Propane
(C3H8)
|
ALL
|
|
|
|
5
|
Manifold
Type
|
|
A
|
Aluminum
w/ 321 SS Wings
|
ALL
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0050
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0100
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0150
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0200
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0250
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0300
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0350
|
|
|
B
|
Aluminum
w/ 330 SS Wings
|
0400
|
|
|
|
6
|
Mounting
Flange
|
|
C
|
Continuous
Mounting Flange, 3 in. position
|
0100
|
|
|
C
|
Continuous
Mounting Flange, 3 in. position
|
0150
|
|
|
C
|
Continuous
Mounting Flange, 3 in. position
|
0200
|
|
|
C
|
Continuous
Mounting Flange, 3 in. position
|
0250
|
|
|
C
|
Continuous
Mounting Flange, 3 in. position
|
0350
|
|
|
C
|
Continuous
Mounting Flange, 3 in. position
|
0400
|
|
|
C
|
Continuous
Mounting Flange,3 in. position
|
0300
|
|
|
C
|
Continuous
Mounting Flange,3 in.position
|
0050
|
|
|
D
|
Brackets
for Duct Mounting
|
ALL
|
|
|
E
|
Dual
Brackets for Rack Mounting
|
ALL
|
|
|
F
|
Continuous
Mounting Flange,4.13 in. position
|
0050
|
|
|
F
|
Continuous
Mounting Flange,4.13 in. position
|
0100
|
|
|
F
|
Continuous
Mounting Flange,4.13 in. position
|
0150
|
|
|
F
|
Continuous
Mounting Flange,4.13 in. position
|
0200
|
|
|
F
|
Continuous
Mounting Flange,4.13 in. position
|
0250
|
|
|
F
|
Continuous
Mounting Flange,4.13 in. position
|
0300
|
|
|
F
|
Continuous
mounting Flange,4.13 in. position
|
0350
|
|
|
F
|
Continuous
Mounting Flange,4.13 in. position
|
0400
|
|
|
S
|
Brackets
for Slot Firing
|
ALL
|
|
|
X
|
No
Mounting Flange
|
ALL
|
|
|
|
7
|
Burner
Configuration
|
|
L
|
Left
Hand Piping
|
ALL
|
|
|
R
|
Right
Hand Piping
|
ALL
|
|
|
|
8
|
Gas Pipe
Connections
|
|
|
9
|
Control
Valve
|
|
R
|
Reduced
Port, Packaged
|
ALL
|
|
|
S
|
Reduced
Port, Separate
|
ALL
|
|
|
X
|
Less
Control Valve
|
ALL
|
|
|
|
10
|
Ignition
Type
|
|
D
|
Direct
Spark
|
ALL
|
|
|
P
|
Pilot
|
ALL
|
|
|
|
11
|
Flame
Supervision
|
|
F
|
Flame
Rod
|
ALL
|
|
|
X
|
No
Sensor Included
|
ALL
|
|
|
|
12
|
Control
Motor
|
|
G
|
EMP-423-4
|
ALL
|
|
|
H
|
EMP-424-4
|
ALL
|
|
|
L
|
Eclipse
Rotary Actr,LH
|
ALL
|
|
|
M
|
Eclipse
Rotary Actr,RH
|
ALL
|
|
|
N
|
Bracket
Only, Honeywell
|
ALL
|
|
|
P
|
Bracket
Only, EMP
|
ALL
|
|
|
Q
|
M7284
C 1000
|
ALL
|
|
|
R
|
Bracket
Only, Eclipse Rotary Actuator
|
ALL
|
|
|
S
|
Eclipse
Rotary Actuator 240V,LH
|
ALL
|
|
|
T
|
Eclipse
Rotary Actuator 240V,RH
|
ALL
|
|
|
X
|
Less
Control Motor and Bracket
|
ALL
|
|
|
|
13
|
Air
Pressure Switch
|
|
C
|
Antunes
JD-2 Blue, .07-1.7 w.c.
|
ALL
|
|
|
D
|
Dungs,
AA-A2-6-2, .16-1.2 w.c.
|
ALL
|
|
|
E
|
Dungs,
AA-A2-4-2, .16-1.2 w.c.
|
ALL
|
|
|
F
|
Antunes,JD-2
Blue,w/S.S. Brd Hose
|
ALL
|
|
|
G
|
Dungs,AA-A2-6-2,w/S.S.
Brd Hose
|
ALL
|
|
|
X
|
No
Pressure Switch
|
ALL
|
|
|
|
14
|
Blower
Model
|
|
B0000
|
No
Blower
|
ALL
|
|
|
B0050
|
Blower,(54-54s-1/3
60Hz or MN402 50Hz)
|
0050
|
|
|
B0100
|
Blower,(54-54s-1/3
60Hz or MN402 50Hz)
|
0100
|
|
|
B0150
|
Blower,(54-54s-1/3
60Hz or MN502 50Hz)
|
0150
|
|
|
B0200
|
Blower,(65-84s-1/3
60Hz or MN502 50Hz)
|
0200
|
|
|
B0250
|
Blower,(65-84s-1/3
60Hz 0r MN502 50Hz)
|
0250
|
|
|
B0300
|
Blower,(65-84s-1/3
60Hz or MN602 50Hz)
|
0300
|
|
|
B0350
|
Blower,(65-84s-1/2
60Hz or MN602 50Hz)
|
0350
|
|
|
B0400
|
Blower,(65-84s-1/2
60Hz or MN602 50Hz)
|
0400
|
|
|
|
15
|
Power
Supply Frequency
|
|
1
|
60
Hz
|
ALL
|
|
|
2
|
50
Hz
|
ALL
|
|
|
X
|
NA
|
ALL
|
|
|
|
16
|
Blower
Motor Type
|
|
AA
|
115/208-230/1
TEFC
|
ALL
|
|
|
AB
|
208-230/460/3
TEFC
|
0200,0250,0300,0350,0400
|
|
|
AC
|
| |