Ratiomatic v1.0 0750- 2500 Configuration chart

Ratiomatic v1.0 Spare Parts

Ratiomatic v3.0 Configuration chart

Ratiomatic v3 050 & 075 Spare Parts

Ratiomatic v3 100 & 200 Spare Parts

Ratiomatic v3 300 & 400 Spare Parts

Ratiomatic v3 500 & 700 Spare Parts

Winnox v1.1 Configuration Chart

Winnox v1 Spare Parts

ThermAir v.1.3 Configuration Chart

ThermAir v.1 15, 25, 40, 75, 100, 200 Spare Parts

ThermAir v.1 300, 400, 500 Spare Parts

RatioAir v1.0 Configuration Chart

RatioAir v1.0 100, 200 Spare Parts

RatioAir v1.0 300, 500 Spare Parts

Mark IV Burners & Spare Parts

Air Heat v1.1 Configuration Chart

Air Heat v1 Spares & Stripped Parts

Air Heat v2.0 Configuration Chart

Air Heat v2 Spare Parts

Furnace Type Burners

ThermJet v. 2.2 Configuration Chart

ThermJet Spare Parts

HVTA-MVTA Spare Parts

MVTA-PCA Spare Parts

Extenso-Jet

Convecto-Flame

Vortometric v. 3.0 Configuration Chart

Vortometric Burner Spare Parts

DSF/DSF-CGO Burners & Spare Parts

PM, PMP & PMI Burners & Spare Parts

JIB, SIB Burners & Spare Parts

Gas-Pak Burners & Spare Parts

Tube Firing Burners

Therm Theif v. 2.1 Configuration Chart

Therm Theif TBF 030, 075, 200 Spare Parts

Bayonet Recuperator v. 1.0 Configuration Chart

Metallic Auto - Recupe

SiC Auto - Recupe

Immerso Jet v. 2.2 Configuration Chart

Immerso Jet Burners

Immerso Pak v2.0 Configuration Chart

16 & 20 IP Burners

100 IP Burners

TBF-CGO Burners

Miscellaneous Burners

Incini-Cone Burners

Blast Tips

Open Burner Nozzles

Line Burners

Heat Exchangers

Extern-a-therm Recupes

Air & Fuel Supply Componets

SMJ Blower v. 1.0 Configuration Chart

SMJ Blowers

Packaged Blowers

Airjectors

Hermetic Boosters

Atmospheric Mixers & Injectors

Low Press. Mixer Configuration Chart

Vari Set Mixers

Mixing Tees - Two Valve

Minimixers

Gas Pressure Regulators

Zero Governors

Gas Shut-Off & Control Valves

Gas Cocks

Eclipse Butterfly Valves

Hot Air Butterfly Valves

ALO-r, ALO Valves

Adjustable Orifice Gas Cocks

Blast Gates

Ratio Regulators

CR Valves

200 Series Locktite Shut Off Valves

2000 AT Autotite Automatic Gas Shut Off

Solenoid Valves

Single Arm Check Valves

Packaged Valve Trains

Dungs Products

Ignition & Supervision Componets, Motors

Pilots

Veri-Flame Monitoring System

Veri-Flame Spare Parts

Multi-Flame Burner Monitoring System

Multi-Flame Spare Parts

Bi-Flame Burner Monitoring System

Peek-A-Flame

Accessories

Ignition Transformers

Motors Used On Eclipse Equipment

Peepsights

Process Measurement & Control

ACT004 - Programmable Rotary Actuator

Air & Gas Metering Orifices

Air & Gas Pressure Gauges


WINNOX1.1

Feature
Description
Option
Option Description
Model
1
Model
0100
Model Size 100
0200
Model Size 200
0300
Model Size 300
0400
Model Size 400
0500
Model Size 500
0600
Model Size 600
1000
Model Size 1000
2
Body Style
S
Standard Body
ALL
3
Fuel Type
B
Butane (C4H10)
0300,0400,0500,0600
N
Natural Gas (CH4)
ALL
P
Propane (C3H8)
0100,0200,0300,0400,0500,0600
4
Air Supply
A
Integral Packaged Blower
ALL
G
Weld Inlet, No BV
ALL
5
Combustion Chamber
A
Alloy Tube (800 Degree)
1000
A
Alloy Tube (Low Temp, SS310)
0100,0200,0300,0400,0500,0600
B
Alloy Tube (1600 Degree Max.)
0100,0200
B
Alloy Tube(1200 Degrees)
0500,0600
B
Alloy Tube(1350 Degree)
0300,0400
B
Alloy Tube(900 Degree)
1000
C
Block and Holder (for 1800 degrees)
0100
C
Block and Holder (for 1800 degrees)
0200
C
Block and Holder for (1800 Degrees)
0300,0400
C
Block and Holder for (1800 Degrees)
0500,0600
6
Control Motor
G
EMP-423-4
ALL
H
EMP-424-4
ALL
M
Eclipse Rotary Actuator
ALL
N
Bracket Only, Honeywell
ALL
P
Bracket Only, Eclipse
ALL
Q
M7284C1000
ALL
R
Bracket Only, Eclipse Rotor
ALL
X
Less Control Motor
ALL
7
Burner Configuration
L
Left Hand Piping
ALL
R
Right Hand Piping
ALL
8
Gas Pipe Connection
B
BSP
0100,0200,0300,0400,0500,0600
C
BSP Pilot Ready
0100,0200,0300,0400,0500,0600
N
NPT
ALL
P
NPT Pilot Ready
ALL
9
Flame Supervision
F
Flame Rod
ALL
X
No Sensor Included
ALL
10
Air Flow Switch
A
Dungs, AA-A2-4-5, 2-20 inch w.c.
ALL
X
No Pressure Switch
ALL
11
Limit Switch
A
High and Low Switch
ALL
B
High Switch Only
ALL
C
Low Switch Only
ALL
X
No Limit Switch
ALL
12
Loading Line Tube
A
Plastic
ALL
13
Firing Position
D
Vertical Down Firing
0100,0200,0300,0400,0500,0600,1000
H
Horizontal Firing
ALL
U
Vertical Up Firing
0300,0400,0500,0600,1000
14
Burner Input
X
NA
ALL
15
Blower Model
4
Size 4 Blower
0100
5
Size 5 Blower
0200
6
Size 6 Blower
0300,0400
7
Size 7 Blower
0500,0600
8
Size 8 Blower
1000
X
Less Blower
ALL
16
Power Supply Frequency
1
60 Hz
ALL
2
50 Hz
0300,0400,0500,0600
X
0 Hz
ALL
17
Pressure and Flow
4G
4G Blower
0100
5C
5C Blower
0200
6C
6C Blower
0300
6D
6D Blower
0400
7A
7A Blower
0500
7B
7B Blower
0600
8B
8B Blower
1000
XX
No Blower
ALL
18
Blower Motor Type
AB
208-230/460/3 TEFC (NEMA 60Hz)
ALL
AF
230/460/3/TEFC
1000
BB
460/3 Auto TEFC (NEMA 60Hz)
0100
BB
460/3 Auto TEFC (NEMA 60Hz)
0200
BB
460/3 Auto TEFC (NEMA 60Hz)
0300,0400
BB
460/3 Auto TEFC (NEMA 60Hz)
0500,0600
CA
220-240/380-415/3 TEFC (IEC 50 Hz)
0300,0400,0500,0600
XX
Less Motor
ALL
19
Blower Inlet
A
Grill (provided as standard)
ALL
B
Standard Inlet Filter
0100
B
Standard Inlet Filter
0200
B
Standard Inlet Filter
0300,0400
B
Standard Inlet Filter
0500,0600
B
Standard Inlet Filter
1000
C
Square 20in x 20in Filter (508mm x 508mm)
0100,0200,0300,0400,0500,0600
D
Filter Silencer
0100
D
Filter Silencer
0200,0300,0400
D
Filter Silencer
0500,0600
X
Not Applicable
ALL
20
Blower Configuration
R
Right Hand Motor
ALL
X
No Motor Orientation
ALL
21
Agency
X
Not Applicable
ALL
22
HeatPak
XXXXXXXX
No HeatPak Option
ALL